CU4

Marque: Allen Bradley
Réference: CU4

Description

The CU4 is an off-delay timing unit which can be operated standalone or as an extension of a host relay. The timed outputs are used in applications where power must be maintained for a fixed duration after an input signal is received. For example, driving a power to lock TLS2-GD2 to maintain a guard door in the locked position for a fixed duration after a stop button is pressed. Another example would be maintaining the connection of a drive to a motor until the braking function is achieved, and then dropping out a contactor to remove power to the motor.

The inputs can be connected in either a single channel or dual channel configuration. The inputs must remain open during the complete timing cycle. Closing the contacts before the timing cycle completes causes the timer to be reset to zero.

The CU4 has a redundant structure with two independent safe timer circuits. The outputs include two normally open safety delayed outputs as well as one normally closed auxiliary output. The safety outputs have independent and redundant internal contacts to support the safety function. When used as an extension of a host relay, the normally closed contacts should be used in the feedback loop of the host relay. If used in standalone application, the normally closed contacts can be used to signal an auxiliary device or PLC.

A typical operation starts with power applied to A1/A2 and the input circuits open.

1. Close the B11/B12 and B21/B22 circuits.

    a. The safety outputs (17/18 & 27/28) close immediately.

2. Open the B11/B12 or B21/B22 circuits.

    a. The timing process starts.

    b. The safety outputs (17/18 & 27/28) open after the time expires.

3. Go to Step 1.


Features
 

  • Category 3 per EN 954-1
  • Stop category 1
  • Timed off-delay 0.15…30 s
  • Two safety contacts
  • One auxiliary contact

LED Indicators



Green Power
Green CH1 t1 Active
Green CH2 t2 Active
  

Specifications



Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1
Safety Classification Cat. 3 per EN 954-1 (ISO 13849-1), SIL CL2 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ⋆ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: < 2.16 x 10-9
MTTFd: > 345 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, c-Tick, and BG
Power Supply
Input Power Entry 24V AC/DC, 50/60 Hz; 0.85…1.1 x rated voltage
Power Consumption 2.5 W
Inputs
Safety Inputs 1 N.C. or 2 N.C.
Input Simultaneity Infinite
Reset Automatic
Response Time 30 ms
Outputs
Safety Contacts 2 N.O.
Auxiliary Contacts 1 N.C.
Rated Impulse withstand Voltage 2500V
Switching Current @ Voltage, Min. 10 mA/10V
Fuses, Output External 6 A slow blow or 10 A fast acting
Electrical Life (Operations) 220V AC/4 A/880VA cosf = 0.35…0.1 M
220V AC/1.7 A/375VA cosf = 0.6…0.5 M
30V DC/2 A/60 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 2,000,000 operations
Utilization Category
AC-15 5 A @ 250V AC 5 A @ 125V AC
DC-13 3 A/24V DC  
UL: B300, 5 A/250V AC, 24V DC
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40, DIN 0470/
IP20
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 165 (0.36)
Conductor Size, Max. 0.2…4 mm2 (24…12 AWG)
 
⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection



Inputs Safety Outputs Auxiliary Outputs Time Range Reset Type Power Supply Cat. No.
1 N.C. or 2 N.C. 2 N.O. 1 N.C. 0.15…3s Automatic 24V AC/DC, 50/60 Hz
0.85…1.1 x rated voltage
440R-S23173
0.5…10s 440R-S23174
1.5…30s 440R-S23175
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.



Click to enlarge - 440R-S23173-5_Dim

Block Diagram



Click to enlarge - 440R-S23173-5_Block Diagram

Typical Wiring Diagrams



Click to enlarge - 440R-S23173-5_Wiring 01
 
Dual Channel Wiring to CU4 Inputs
 
Click to enlarge - 440R-S23173-5_Wiring 02
 
Single Channel Wiring to CU4 Inputs

 